PV Electrical Installation Meter | MPI-540-PV

$ 98.10

Note: Prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon at the time of purchase will apply to your order. As an Amazon Associate, we earn from qualifying purchases.
Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Description Multi-function Electrical Installation Meter | MPI-540 Measurement of short circuit loop impedance ZL-PE, ZL-N, ZL-L Test current: 23/40A; measuring range acc. to IEC 61557: 0,13…1999,9 Ω (for 1.2m test lead): Display range Resolution Accuracy 0,000…19,999 Ω 0,001 Ω ±(5% of reading 30 digits) 20,00…199,99 Ω 0,01 Ω ±(5% of reading 30 digits) 200,0…1999,9 Ω 0,1 Ω ±(5% of reading 30 digits) rated voltage: 95…270 V (for ZL-PE and ZL-N) and 95…440 V (for ZL-L) frequency: 45…65 Hz Measurement of short circuit loop impedance ZL-PE in RCD mode Test current: 15mA, measuring range acc. to IEC 61557: 0,50…1999 Ω Display range Resolution Accuracy 0,00…19,99 Ω 0,01 Ω ±(6% of reading 10 digits) 20,0…199,9 Ω 0,1 Ω ±(6% of reading 5 digits) 200…1999 Ω 1 Ω ±(6% of reading 5 digits) rated voltage: 95…270 V frequency: 45…65 Hz Measurement of earth resistance RE with the 3p and 4p method Measuring range acc. to IEC 61557-5: 0,50 Ω…1,99 k Ω for test voltage 50 V 0,56 Ω …1,99 k Ω for test voltage 25 V Display range Resolution Accuracy 0,00…9,99 Ω 0,01 Ω ±(2% of reading 4 digits) 10,0…99,9 Ω 0,1 Ω ±(2% of reading 3 digits) 100…999 Ω 1 Ω ±(2% of reading 3 digits) 1,00…1,99 kΩ 0,01 kΩ ±(2% of reading 3 digits) test voltage: 25 V or 50 V rms test current: 20 mA, sinusoidal rms 125 Hz (for fn = 50 Hz) and 150 Hz (for fn = 60 Hz) measurement blocked at interference voltage UN > 24 V maximum measured interference voltage Unmax = 100 V maximum resistance of auxiliary earth electrodes 50 kΩ Selective earth resistance measurement with clamp (3p clamp) Measuring range acc. to IEC 61557-5: 1 Ω…1,99 kΩ Display range Resolution Accuracy 0,00…9,99 Ω 0,01 Ω ±(2% of reading 4 digits) 10,0…99,9 Ω 0,1 Ω ±(2% of reading 4 digits) 100…999 Ω 1 Ω ±(2% of reading 4 digits) 1,00…1,99 kΩ 0,01 kΩ ±(2% of reading 4 digits) measurement with additional current clamp interference current measuring range: up to 9,99 A Selective earth measurement with two clamps Display range Resolution Accuracy 0,00…9,99 Ω 0,01 Ω ±(10% of reading 4 digits) 10,0…19,9 Ω 0,1 Ω ±(10% of reading 4 digits) 20,0…99,9 Ω 0,1 Ω ±(20% of reading 4 digits) measurement with transmitting and receiving clamps interference current measuring range: up to 9,99 A Soil resistivity measurement (ρ) Display range Resolution Accuracy 0,00…9,99 Ω 0,01 Ω ±(2% of reading 4 digits) 10,0…99,9 Ω 0,1 Ω ±(2% of reading 4 digits) 100…999 Ω 1 Ω ±(2% of reading 4 digits) 1,00…1,99 kΩ 0,01 kΩ ±(2% of reading 4 digits) measurement with Wenner’s method distance settable in metres or feet distance range: 1…30 m (1…90 feet) Phase sequence indication phase sequence indication: conforming, non-conforming mains voltage range U : 100…440 V (45…65 Hz) L-L display of phase-to-phase voltage values Measurements of RCD parameters (voltage range 95…270 V): RCD tripping test and measurement of tripping time tA (for tA measurement function) RCD type Current Range Resolution Accuracy General and short-time delay 0,5*IΔn 0…300 ms 1 ms ±(2% of reading 2 digits) (for RCD with IΔn=10 mA and 0,5xIΔn uncertainty: ±(2% of reading 3 digits) General and short-time delay 1*IΔn 0…300 ms 1 ms ±(2% of reading 2 digits) (for RCD with IΔn=10 mA and 0,5xIΔn uncertainty: ±(2% of reading 3 digits) General and short-time delay 2*IΔn 0…150 ms 1 ms ±(2% of reading 2 digits) (for RCD with IΔn=10 mA and 0,5xIΔn uncertainty: ±(2% of reading 3 digits) General and short-time delay 5*IΔn 0…40 ms 1 ms ±(2% of reading 2 digits) (for RCD with IΔn=10 mA and 0,5xIΔn uncertainty: ±(2% of reading 3 digits) Selective 0,5*IΔn 0…500 ms 1 ms ±(2% of reading 2 digits) (for RCD with IΔn=10 mA and 0,5xIΔn uncertainty: ±(2% of reading 3 digits) Selective 1*IΔn 0…200 ms 1 ms ±(2% of reading 2 digits) (for RCD with IΔn=10 mA and 0,5xIΔn uncertainty: ±(2% of reading 3 digits) Selective 2*IΔn 0…200 ms 1 ms ±(2% of reading 2 digits) (for RCD with IΔn=10 mA and 0,5xIΔn uncertainty: ±(2% of reading 3 digits) Selective 5*IΔn 0…150 ms 1 ms ±(2% of reading 2 digits) (for RCD with IΔn=10 mA and 0,5xIΔn uncertainty: ±(2% of reading 3 digits) accuracy of residual current application: for 0,5*IΔn:-8…0% for 1*IΔn, 2*IΔn, 5*IΔn: 0…8% measurement of RCD tripping current IΔn for sinusoidal residual current (AC type) Rated current Meas. range Resolution Test current Accuracy 10 mA 3,3…10,0 mA 0,1 mA 0,3 x IΔn…1,0 x IΔn ± 5% IΔn 30 mA 9,0…30,0 mA 0,1 mA 0,3 x IΔn…1,0 x IΔn ± 5% IΔn 100 mA 33…100 mA 1 mA 0,3 x IΔn…1,0 x IΔn ± 5% IΔn 300 mA 90…300 mA 1 mA 0,3 x IΔn…1,0 x IΔn ± 5% IΔn 500 mA 150…500 mA 1 mA 0,3 x IΔn…1,0 x IΔn ± 5% IΔn 1000 mA 330…1000 mA 1 mA 0,3 x IΔn…1,0 x IΔn ± 5% IΔn the measurement can be started from positive or negative half-period of forced leakage current (AC) Measurement of RCD tripping current IA for unidirectional residual current and unidirectional with the 6 mA DC bias (type A) Rated current Meas. range Resolution Test current Accuracy 10 mA 3,5…20,0 mA 0,1 mA 0,35 x IΔn…2,0 x IΔn ± 10% IΔn 30 mA 10,5…42,0 mA 0,1 mA 0,35 x IΔn…1,4 x IΔn ± 10% IΔn 100 mA 35…140 mA 1 mA 0,35 x IΔn…1,4 x IΔn ± 10% IΔn 300 mA 105…420 mA 1 mA 0,35 x IΔn…1,4 x IΔn ± 10% IΔn 500 mA 175…700 mA 1 mA 0,35 x IΔn…1,4 x IΔn ± 10% IΔn measurement for positive or negative half-periods of forced leakage current Measurement of RCD tripping current I for direct residual current (type B) Rated current Meas. range Resolution Test current Accuracy 10 mA 2,0…20,0 mA 0,1 mA 0,2 x IΔn…2,0 x IΔn ± 10% IΔn 30 mA 6…60 mA 1 mA 0,2 x IΔn…2,0 x IΔn ± 10% IΔn 100 mA 20…200 mA 1 mA 0,2 x IΔn…2,0 x IΔn ± 10% IΔn 300 mA 60…600 mA 1 mA 0,2 x IΔn…2,0 x IΔn ± 10% IΔn 500 mA 100…1000 mA 1 mA 0,2 x IΔn…2,0 x IΔn ± 10% IΔn measurement for positive or negative half-periods of forced leakage current IΔn – rated residual current Insulation resistance measurements Measuring range acc. to IEC 61557-2: for Un = 50 V: 50 kΩ…250 MΩ for Un = 100 V: 100 kΩ…500 MΩ for Un = 250 V: 250 kΩ…999 MΩ for Un = 500 V: 500 kΩ…2 GΩ for Un = 1000 V: 1 MΩ…9,99 GΩ Display range *) Resolution Accuracy 0,00…9,99 Ω 0,01 Ω ±(3% of reading 8 digits) 10,0…19,9 Ω 0,1 Ω ±(3% of reading 8 digits) 20,0…99,9 Ω 0,1 Ω ±(3% of reading 8 digits) 20,0…99,9 Ω 0,1 Ω ±(3% of reading 8 digits) 20,0…99,9 Ω 0,1 Ω ±(4% of reading 6 digits) *) not greater than measuring range for given voltage Low-voltage measurement of resistance and circuit continuity Measurement of protective conductor continuity with the ±200 mA current Display range Resolution Accuracy 0,00…19,99 Ω 0,01 Ω ±(2% of reading 3 digits) 20,0…199,9 Ω 0,1 Ω ±(2% of reading 3 digits) 200…400 Ω 1 Ω ±(2% of reading 3 digits) voltage on open terminals: 4…9 V output current at R < 2 Ω: min. 200 mA autocalibration of test leads measurements for both current polarities Illuminance measurement Display range Resolution Accuracy 0,1…99,9 lx 0,1 lx ±(5% of reading 2 digits) 100…999 lx 1 lx ±(5% of reading 2 digits) 1,00…9,99 klx 0,01 klx ±(5% of reading 2 digits) 10,0…19,9 klx 0,1 klx ±(5% of reading 2 digits) measurement in luxes (lx) or feet-candles (fc) Three-phase recorder of electrical network parameters The device is designed to work with networks: with nominal frequency 50/60 Hz with nominal voltage: 64/110 V 110/190 V 115/200 V 127/220 V 220/380 V 230/400 V 240/415 V 254/440 V 290/500 V DC network Supported networks: single-phase two-phase with common N conductor, three-phase star connection N with and without conductor three-phase delta Parameters of analyzer: Parameter Measurement range Max. resolution Accuracy Alternating voltage (TRMS) – 0,0…500 V 0,01 % Unom ±0,5% Unom Alternating current TRMS – depending on clamp* 0,01% Inom ±2% of reading for reading of ≥ 10% Inom ±2% Inom for reading of < 10% Inom (error does not account for clamps error) Frequency – 40,00…70,00 Hz 0,01 Hz ±0,05 Hz Active, reactive, apparent and distortion power – depending of configuration (transformers, clamp) up to for decimal places depending of configuration (transformers, clamp) Active, reactive apparent energy – depending of configuration (transformers, clamp) up to for decimal places as power error cosφ and power factor (PF – 0,00…1,00 0,01 ±0,03 Harmonics Voltage as for alternating voltage as for alternating voltage ±5% of reading for reading of ≥ 3% Unom ±0,15% Unom for reading of < 3% Unom Harmonics Current as for alternating voltage as for alternating voltage ±5% of reading for reading of ≥ 10% Inom ±0,5% Inom for reading of < 10% Inom THD Voltage 0.0…100.0% (in regards to the rms value) 0,1% ±5% THD Current 0.0…100.0% (in regards to the rms value) 0,1% ±5% Voltage asymmetry Voltage and current 0,0…10,0% 0,1% ±0,15% (absolute error) * Clamp F-1A, F-2A, F-3A: 0..3000 A (10000 Ap-p ) * Clamp C-4A: 0..1000 A (3600 Ap-p ) * Clamp C-5A: 0..1000 A (3600 Ap-p ) * Clamp C-6A: 0..10 A (36 Ap-p ) * Clamp C-7A: 0…100 A (360 Ap-p ) Clamps C-4A WACEGC4AOKR C-5A WACEGC5AOKR C-6A WACEGC6AOKR C-7A WACEGC7AOKR F-1A WACEGF1AOKR F-2A WACEGF2AOKR F-3A WACEGF3AOKR Rated current 1000 A AC 1000 A AC 1400 A DC 0 A AC 100 A AC 3000 A AC 3000 A AC 3000 A AC Max. overload current 1200 A AC 1000 A AC 3000 A DC 20 A AC 100 A AC 10k A AC 10k A AC 10k A AC Minimal measurable current 100 mA 500 mA 10 mA 20 mA 1 A 1 A 1 A Frequency 30 Hz…10 kHz DC…5 kHz 40 Hz…10 kHz 40 Hz…1 kHz 40 Hz…10 kHz 40 Hz…10 kHz 40 Hz…10 kHz Imput signal level 1 mV / 1 A 1 mV / 1 A 100 mV / 1 A 500 mV / 1A 38,8 μV / 1 A 38,8 μV / 1 A 38,8 μV / 1 A Max. diameter of measured cord 52 mm 39 mm 20 mm 24 mm 360 mm 235 mm 120 mm Minimal basic accuracy ≤0,5% ≤1,5% ≤1% 0,5% 1% 1% 1% Battery power supply — — — — — — Lead length 2,2 m 2,2 m 2,2 m 3 m 2,2 m 2,2 m 2,2 m Measurement category IV 300 V IV 300 V IV 300 V III 300 V IV 600 V IV 600 V IV 600 V   Multi-function Electrical Installation Meter | MPI-540
PV Electrical Installation Meter | MPI-540-PV
Compare items
  • Total (0)
Compare
0
Shopping cart